Your browser doesn't support javascript.
loading
: 20 | 50 | 100
1 - 20 de 10.787
1.
Ann Card Anaesth ; 27(1): 65-67, 2024 Jan 01.
Article En | MEDLINE | ID: mdl-38722125

ABSTRACT: One-lung ventilation is indicated during thoracic surgery for visualization and exposure of surgical site. It is achieved with bronchial blockers, double-lumen endobronchial tube, single-lumen endotracheal tubes and Univent tube for infants and children. Fibreoptic bronchoscope is required for placing and confirming the correct position of these tubes. We report a perioperative management of safe conduct of one lung ventilation for a 6-year child undergoing left lower lobe lobectomy through C-MAC video laryngoscope guided two single lumen tubes in limited resource settings where paediatric-sized fibreoptic bronchoscope is unavailable.


Intubation, Intratracheal , One-Lung Ventilation , Humans , One-Lung Ventilation/methods , One-Lung Ventilation/instrumentation , Intubation, Intratracheal/methods , Intubation, Intratracheal/instrumentation , Child , Male , Bronchoscopy/methods , Fiber Optic Technology , Female , Laryngoscopy/methods
3.
Scand J Trauma Resusc Emerg Med ; 32(1): 40, 2024 May 10.
Article En | MEDLINE | ID: mdl-38730289

BACKGROUND: Pre-hospital endotracheal intubation (ETI) is a sophisticated procedure with a comparatively high failure rate. Especially, ETI in confined spaces may result in higher difficulty, longer times, and a higher failure rate. This study analyses if Helicopter Emergency Medical Services (HEMS) intubation (time-to) success are influenced by noise, light, and restricted space in comparison to ground intubation. Available literature reporting these parameters was very limited, thus the reported differences between ETI in helicopter vs. ground by confronting parameters such as time to secure airway, first pass success rate and Cormack-Lehane Score were analysed. METHODS: A systematic review and meta-analysis were conducted using PUBMED, EMBASE, Cochrane Library, and Ovid on October 15th, 2022. The database search provided 2322 studies and 6 studies met inclusion and quality criteria. The research was registered with the International Prospective Register of Systematic Reviews (CRD42022361793). RESULTS: A total of six studies were selected and analysed as part of the systematic review and meta-analysis. The first pass success rate of ETI was more likely to fail in the helicopter setting as compared to the ground (82,4% vs. 87,3%), but the final success rate was similar between the two settings (96,8% vs. 97,8%). The success rate of intubation in literature was reported higher in physician-staffed HEMS than in paramedic-staffed HEMS. The impact of aircraft type and location inside the vehicle on intubation success rates was inconclusive across studies. The meta-analysis revealed inconsistent results for the mean duration of intubation, with one study reporting shorter intubation times in helicopters (13,0s vs.15,5s), another reporting no significant differences (16,5s vs. 16,8s), and a third reporting longer intubation times in helicopters (16,1s vs. 15,0s). CONCLUSION: Further research is needed to assess the impact of environmental factors on the quality of ETI on HEMS. While the success rate of endotracheal intubation in helicopters vs. on the ground is not significantly different, the duration and time to secure the airway, and Cormack-Lehane Score may be influenced by environmental factors. However, the limited number of studies reporting on these factors highlights the need for further research in this area.


Air Ambulances , Emergency Medical Services , Intubation, Intratracheal , Intubation, Intratracheal/methods , Humans , Emergency Medical Services/methods
4.
Cochrane Database Syst Rev ; 5: CD012712, 2024 May 02.
Article En | MEDLINE | ID: mdl-38695628

BACKGROUND: Respiratory distress occurs in up to 7% of newborns, with respiratory support (RS) provided invasively via an endotracheal (ET) tube or non-invasively via a nasal interface. Invasive ventilation increases the risk of lung injury and chronic lung disease (CLD). Using non-invasive strategies, with or without minimally invasive surfactant, may reduce the need for mechanical ventilation and the risk of lung damage in newborn infants with respiratory distress. OBJECTIVES: To evaluate the benefits and harms of nasal high-frequency ventilation (nHFV) compared to invasive ventilation via an ET tube or other non-invasive ventilation methods on morbidity and mortality in preterm and term infants with or at risk of respiratory distress. SEARCH METHODS: We searched CENTRAL, MEDLINE, Embase, CINAHL and three trial registries in April 2023. SELECTION CRITERIA: Randomised controlled trials (RCTs), cluster- or quasi-RCTs of nHFV in newborn infants with respiratory distress compared to invasive or non-invasive ventilation. DATA COLLECTION AND ANALYSIS: Two authors independently selected the trials for inclusion, extracted data, assessed the risk of bias, and undertook GRADE assessment. MAIN RESULTS: We identified 33 studies, mostly in low- to middle-income settings, that investigated this therapy in 5068 preterm and 46 term infants. nHFV compared to invasive respiratory therapy for initial RS We are very uncertain whether nHFV reduces mortality before hospital discharge (RR 0.67, 95% CI 0.20 to 2.18; 1 study, 80 infants) or the incidence of CLD (RR 0.38, 95% CI 0.09 to 1.59; 2 studies, 180 infants), both very low-certainty. ET intubation, death or CLD, severe intraventricular haemorrhage (IVH) and neurodevelopmental disability (ND) were not reported. nHFV vs nasal continuous positive airway pressure (nCPAP) used for initial RS We are very uncertain whether nHFV reduces mortality before hospital discharge (RR 1.00, 95% CI 0.41 to 2.41; 4 studies, 531 infants; very low-certainty). nHFV may reduce ET intubation (RR 0.52, 95% CI 0.33 to 0.82; 5 studies, 571 infants), but there may be little or no difference in CLD (RR 1.35, 95% CI 0.80 to 2.27; 4 studies, 481 infants); death or CLD (RR 2.50, 95% CI 0.52 to 12.01; 1 study, 68 participants); or severe IVH (RR 1.17, 95% CI 0.36 to 3.78; 4 studies, 531 infants), all low-certainty evidence. ND was not reported. nHFV vs nasal intermittent positive-pressure ventilation (nIPPV) used for initial RS nHFV may result in little to no difference in mortality before hospital discharge (RR 1.86, 95% CI 0.90 to 3.83; 2 studies, 84 infants; low-certainty). nHFV may have little or no effect in reducing ET intubation (RR 1.33, 95% CI 0.76 to 2.34; 5 studies, 228 infants; low-certainty). There may be a reduction in CLD (RR 0.63, 95% CI 0.42 to 0.95; 5 studies, 307 infants; low-certainty). A single study (36 infants) reported no events for severe IVH. Death or CLD and ND were not reported. nHFV vs high-flow nasal cannula (HFNC) used for initial RS We are very uncertain whether nHFV reduces ET intubation (RR 2.94, 95% CI 0.65 to 13.27; 1 study, 37 infants) or reduces CLD (RR 1.18, 95% CI 0.46 to 2.98; 1 study, 37 participants), both very low-certainty. There were no mortality events before hospital discharge or severe IVH. Other deaths, CLD and ND, were not reported. nHFV vs nCPAP used for RS following planned extubation nHFV probably results in little or no difference in mortality before hospital discharge (RR 0.92, 95% CI 0.52 to 1.64; 6 studies, 1472 infants; moderate-certainty). nHFV may result in a reduction in ET reintubation (RR 0.42, 95% CI 0.35 to 0.51; 11 studies, 1897 infants) and CLD (RR 0.78, 95% CI 0.67 to 0.91; 10 studies, 1829 infants), both low-certainty. nHFV probably has little or no effect on death or CLD (RR 0.90, 95% CI 0.77 to 1.06; 2 studies, 966 infants) and severe IVH (RR 0.80, 95% CI 0.57 to 1.13; 3 studies, 1117 infants), both moderate-certainty. We are very uncertain whether nHFV reduces ND (RR 0.92, 95% CI 0.37 to 2.29; 1 study, 74 infants; very low-certainty). nHFV versus nIPPV used for RS following planned extubation nHFV may have little or no effect on mortality before hospital discharge (RR 1.83, 95% CI 0.70 to 4.79; 2 studies, 984 infants; low-certainty). There is probably a reduction in ET reintubation (RR 0.69, 95% CI 0.54 to 0.89; 6 studies, 1364 infants), but little or no effect on CLD (RR 0.88, 95% CI 0.75 to 1.04; 4 studies, 1236 infants); death or CLD (RR 0.92, 95% CI 0.79 to 1.08; 3 studies, 1070 infants); or severe IVH (RR 0.78, 95% CI 0.55 to 1.10; 4 studies, 1162 infants), all moderate-certainty. One study reported there might be no difference in ND (RR 0.88, 95% CI 0.35 to 2.16; 1 study, 72 infants; low-certainty). nHFV versus nIPPV following initial non-invasive RS failure nHFV may have little or no effect on mortality before hospital discharge (RR 1.44, 95% CI 0.10 to 21.33); or ET intubation (RR 1.23, 95% CI 0.51 to 2.98); or CLD (RR 1.01, 95% CI 0.70 to 1.47); or severe IVH (RR 0.47, 95% CI 0.02 to 10.87); 1 study, 39 participants, all low- or very low-certainty. Other deaths or CLD and ND were not reported. AUTHORS' CONCLUSIONS: For initial RS, we are very uncertain if using nHFV compared to invasive respiratory therapy affects clinical outcomes. However, nHFV may reduce intubation when compared to nCPAP. For planned extubation, nHFV may reduce the risk of reintubation compared to nCPAP and nIPPV. nHFV may reduce the risk of CLD when compared to nCPAP. Following initial non-invasive respiratory support failure, nHFV when compared to nIPPV may result in little to no difference in intubation. Large trials, particularly in high-income settings, are needed to determine the role of nHFV in initial RS and following the failure of other non-invasive respiratory support. Also, the optimal settings of nHVF require further investigation.


High-Frequency Ventilation , Infant, Premature , Noninvasive Ventilation , Randomized Controlled Trials as Topic , Respiratory Distress Syndrome, Newborn , Humans , Infant, Newborn , Respiratory Distress Syndrome, Newborn/therapy , Respiratory Distress Syndrome, Newborn/mortality , Noninvasive Ventilation/methods , High-Frequency Ventilation/methods , Bias , Intubation, Intratracheal/methods , Pulmonary Surfactants/therapeutic use
5.
BMC Anesthesiol ; 24(1): 166, 2024 May 03.
Article En | MEDLINE | ID: mdl-38702641

BACKGROUND: Pregnancy is associated with an increased risk of pulmonary aspiration during general anaesthesia, but the incidence of this complication is not well defined. METHODS: We performed a retrospective database review in a tertiary care university hospital to determine the incidence of pulmonary aspiration in pregnant patients undergoing endotracheal intubation, with and without Rapid Sequence Induction (RSI), as well as face-mask ventilation and supraglottic airway devices. We included Patients in the 2nd or 3rd trimester of pregnancy and immediate postpartum undergoing surgical procedures. The primary endpoint was the occurrence of pulmonary aspiration. RESULTS: Data from 2,390 patients undergoing general anaesthesia for cerclage of cervix uteri, manual removal of retained placenta, repair of obstetric laceration, or postpartum bleeding were retrospectively evaluated. A supraglottic airway device or face-mask ventilation was used in 1,425/2,390 (60%) of patients, while 638/2,390 (27%) were intubated. RSI was used in 522/638 (82%) of patients undergoing tracheal intubation, or 522/2,390 (22%) of the entire cohort. In-depth review of the charts, including 54 patients who had been initially classified as "possible pulmonary aspiration" by anaesthetists, revealed that this adverse event did not occur in the cohort. CONCLUSIONS: In conclusion, in this obstetric surgery patient population at risk for pulmonary aspiration, supraglottic airway devices were used in approximately 60% of cases. Yet, no aspiration event was detected with either a supraglottic airway or endotracheal intubation.


Airway Management , Hospitals, University , Intubation, Intratracheal , Respiratory Aspiration , Humans , Female , Retrospective Studies , Pregnancy , Adult , Airway Management/methods , Intubation, Intratracheal/methods , Respiratory Aspiration/prevention & control , Respiratory Aspiration/etiology , Postpartum Period , Tertiary Care Centers , Anesthesia, General/methods
8.
Adv Emerg Nurs J ; 46(2): 126-140, 2024.
Article En | MEDLINE | ID: mdl-38736097

Ensuring correct placement of the endotracheal tube (ETT) during intubation is an important step to avoid complications. Appropriate placement of the ETT can be challenging and, if done incorrectly, can lead to complications such as hypoxemia, atelectasis, hyperinflation, barotrauma, cardiovascular instability, end organ damage, and even death. Although several procedures exist to help assess ETT confirmation, all have limitations, are not always reliable, and vary in their degree of accuracy. Point-of-care ultrasound (POCUS) has emerged as a useful tool in the emergency department for quick diagnosis and treatment of many emergency conditions (Gonzalez et al., 2020). The purpose of this paper is to describe a systematic approach for the emergency nurse practitioner to use POCUS to assess proper endotracheal placement and the positioning within the trachea based on prior studies that compare this modality to traditional ones.


Intubation, Intratracheal , Nurse Practitioners , Point-of-Care Systems , Ultrasonography , Humans , Intubation, Intratracheal/nursing , Intubation, Intratracheal/methods , Emergency Service, Hospital , Emergency Nursing
11.
Anaesthesiol Intensive Ther ; 56(1): 37-46, 2024.
Article En | MEDLINE | ID: mdl-38741442

INTRODUCTION: Cricothyrotomy (CTM) is currently recommended as the preferred method due to its ease, speed, and safety in life-threatening airway emergencies where standard tracheal intubation and mask ventilation fail. MATERIAL AND METHODS: This retrospective study analyzed 33 cases of "can't intubate, can't oxygenate or ventilate" (CICOV): 12 of percutaneous dilatational tracheostomy (PDT) and 21 of CTM. The CTM group was younger (median age 44) and mainly consisted of trauma patients. The PDT group was more diverse and procedures were performed by anesthesia and critical care consultants. RESULTS: Initial success rates were 100% for PDT (12/12) and 86% for CTM (18/21), with one conversion from CTM to PDT. No perioperative complications occurred in the PDT group, while the CTM group experienced two cases of false tracts requiring re-do and three cases of bleeding. Immediate mortality within 24 hours was reported in 5/19 CTM patients and none in the PDT group. Successful liberation from mechanical ventilation at hospital discharge was achieved in 6/12 PDT patients and 11/21 CTM patients. Among the 21 CTM cases, all 16 survivors underwent subsequent tracheostomy. Tracheal decannulation occurred in 4/12 PDT patients and 10/21 CTM patients. Favorable immediate neurological outcomes (GCS ≥ 11T) were observed in 8/12 PDT patients and 8/21 CTM patients, while 3 PDT patients remained anesthetized until death and 7 CTM patients died within the first 72 hours without recovery attempts. CONCLUSIONS: In experienced hands, PDT could be a legitimate clinical option for the surgical airway in cases of CICOV. CTM may be more suitable for practitioners who encounter CICOV infrequently.


Tracheostomy , Humans , Retrospective Studies , Male , Female , Middle Aged , Adult , Tracheostomy/methods , Aged , Intubation, Intratracheal/methods , Respiration, Artificial/methods , Cricoid Cartilage/surgery , Young Adult , Airway Management/methods
12.
Anaesthesiol Intensive Ther ; 56(1): 47-53, 2024.
Article En | MEDLINE | ID: mdl-38741443

INTRODUCTION: Laryngeal mask airway-blockbuster (LMA-BT) is a relatively new supraglottic airway device (SGAD). In this study, we compared LMA-BT with I-Gel LMA for efficacy of blind tracheal intubation. MATERIAL AND METHODS: We conducted a single-blind prospective study after ethical approval. One hundred American Society of Anesthesiology (ASA) Grade I-III (age 18-60 years) patients scheduled for elective surgery under general anaesthesia with endotracheal intubation were included and randomly divided into 2 groups. Blind tracheal intubation was performed through LMA-BT ( n = 50) and I-Gel ( n = 50) in groups 1 and 2, respectively. The primary aim was to evaluate the first pass success rate of blind tracheal intubation through the LMAs. The secondary objectives noted were attempts and ease of LMA insertion, total time taken for LMA insertion, airway seal pressure of LMA, ease of NGT insertion through LMA, fibre-optic grading of laryngeal view through LMA, overall success rate and time of intubation through LMA, time for LMA removal, and complications, if any. RESULTS: In the LMA-BT group, the first pass success rate ( P < 0.019) and the overall success rate of intubation ( P < 0.005) were significantly higher than in the I-Gel group. Using LMA-BT also resulted in statistically significant shorter intubation time ( P < 0.0001) with higher airway seal pressure as compared to I-Gel ( P < 0.001). The difference in the first attempt insertion, number of insertion attempts, ease and time of LMA insertion and removal after intubation, and postoperative complications were comparable among the groups. CONCLUSIONS: LMA-BT is a superior device as compared to I-Gel LMA as a conduit for blind tracheal intubation.


Anesthesia, General , Intubation, Intratracheal , Laryngeal Masks , Humans , Intubation, Intratracheal/methods , Intubation, Intratracheal/instrumentation , Single-Blind Method , Adult , Prospective Studies , Female , Male , Middle Aged , Anesthesia, General/methods , Young Adult , Adolescent
14.
Anaesthesiologie ; 73(5): 340-347, 2024 May.
Article De | MEDLINE | ID: mdl-38625537

BACKGROUND: Endotracheal suctioning in intubated or tracheotomized critically ill patients is a daily task of various professional groups in intensive and emergency medicine; however, a German language summary of current evidence is lacking. OBJECTIVE: The aim is to develop a narrative overview of current evidence on endotracheal suctioning of intubated or tracheotomized patients in the clinical setting. MATERIAL AND METHODS: A literature search was conducted in the databases Cinahl, Cochrane Library, Livivo, and Medline via PubMed by nurses with an academic degree. In addition, a hand search and applying the snowball principle were performed. Following a successful critical appraisal, all English and German language publications addressing endotracheal suctioning in the context of hospital care were included. RESULTS: A total of 23 full texts were included. After developing 6 main topics on endotracheal suction 19 articles were considered in the reporting. The results showed, among others, that routine deep suctioning once per shift is contraindicated and that the catheter should be advanced no more than 0.5-1 cm beyond the distal end of the tube or tracheal cannula. Closed suction catheters offer advantages, especially for staff protection, although studies are heterogeneous. Further training of staff is obligatory. CONCLUSION: Few conclusive studies on endotracheal suction could be found; however, with the available evidence initial conclusions can be drawn which should be considered in, for example, internal standard operating procedures. Further research is needed.


Intubation, Intratracheal , Tracheotomy , Suction , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/methods , Humans , Tracheotomy/adverse effects , Tracheotomy/methods
16.
BMC Anesthesiol ; 24(1): 150, 2024 Apr 19.
Article En | MEDLINE | ID: mdl-38641603

BACKGROUND: Double lumen endobronchial tubes (DLTs) are frequently used to employ single lung ventilation strategies during thoracic surgical procedures. Placement of these tubes can be challenging even for experienced clinicians. We hypothesized that airway anatomy, particularly of the glottis and proximal trachea, significantly impacts the ease or difficulty in placement of these tubes. METHODS: Images from 24 randomly selected Positron Emission Tomography - Computed Tomography (PET-CT) scans were evaluated for several anatomic aspects of the upper airway, including size and angulation of the glottis and proximal tracheal using calibrated CT measurements and an online digital protractor. The anatomic issues identified were confirmed in cadaveric anatomic models. RESULTS: Proximal tracheal diameter measurements in PET-CT scans demonstrated a mean ± standard deviation of 20.4 ± 2.5 mm in 12 males and 15.5 ± 0.98 mm in 12 females (p < 0.001), and both were large enough to accommodate 39 French and 37 French DLTs in males and females, respectively. Subsequent measurements of the posterior angulation of the proximal trachea revealed a mean angle of 40.8 ± 5.7 degrees with no sex differences. By combining the 24 individual posterior tracheal angles with the 16 angled distal tip measurements DLTs (mean angle 24.9 ± 2.1 degrees), we created a series of 384 patient intubation angle scenarios. This data clearly showed that DLT rotation to a full 180 degrees decreased the mean intubation angle between the DLT and the proximal trachea from a mean of 66.6 ± 5.9 to only 15.8 ± 5.9 degrees. CONCLUSIONS: Rotation of DLTs a full 180 instead of the recommended 90 degrees facilitates DLT intubations.


Intubation, Intratracheal , Thoracic Surgical Procedures , Male , Female , Humans , Intubation, Intratracheal/methods , Positron Emission Tomography Computed Tomography , Trachea/diagnostic imaging , Glottis
17.
J Clin Anesth ; 95: 111461, 2024 Aug.
Article En | MEDLINE | ID: mdl-38604048

BACKGROUND: There is a search for an ideal agent to facilitate awake fiberoptic intubation (AFOI). Dexmedetomidine is a selective α2 agonist which can be administered through intravenous, intramuscular, buccal, intranasal & inhalational routes. It provides good intubation conditions without oxygen desaturation but may cause hypotension and bradycardia when administered intravenously. Hence, alternative routes of administering dexmedetomidine which may improve its safety profile are worth exploring. METHODS: In this randomised, controlled, double-blind trial, 46 ASA I/II adult participants scheduled for elective ENT surgery were randomly allocated to Group ND (Nebulised Dexmedetomidine) (n = 23) to receive nebulisation with dexmedetomidine 1µg.kg-1 and Group ID (Intravenous Dexmedetomidine) (n = 23) to receive intravenous dexmedetomidine 1µg.kg-1 before AFOI. All the patients received injection midazolam 1 mg i.v. as premedication before anaesthesia was initiated. The primary outcome was the cough score. The secondary outcomes were the RSS, SAYGO boluses, post-intubation score, hemodynamic parameters, recall of the procedure, patient satisfaction score and any side effects. RESULTS: The cough score was significantly lower in nebulized group (2.43 ± 0.992 vs 3.52 ± 1.082) with p = 0.001. RSS(3.30 ± 0.926 vs 4.22 ± 1.126; p = 0.004), number of SAYGO boluses required (2.74 ± 0.864 vs 3.57 ± 1.161; p = 0.009) & the post intubation score (1.48 ± 0.593 vs 2.17 ± 0.778; p = 0.001) were also significantly lower in nebulized group. CONCLUSIONS: Nebulisation with dexmedetomidine results in desirable degree of sedation and better tolerance of the procedure with adequate attenuation of the haemodynamic responses to intubation.


Dexmedetomidine , Fiber Optic Technology , Hypnotics and Sedatives , Intubation, Intratracheal , Nebulizers and Vaporizers , Humans , Dexmedetomidine/administration & dosage , Dexmedetomidine/adverse effects , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/methods , Double-Blind Method , Male , Female , Adult , Middle Aged , Hypnotics and Sedatives/administration & dosage , Hypnotics and Sedatives/adverse effects , Patient Satisfaction , Administration, Inhalation , Wakefulness/drug effects , Young Adult , Administration, Intravenous
18.
J Vis Exp ; (205)2024 Mar 15.
Article En | MEDLINE | ID: mdl-38557448

Endotracheal intubation and subsequent ventilation are often basic requirements for translational research in rat models for various interventions that require controlled or high ventilation pressures or access to the thoracic cavity and organs. Conventional endoorotracheal intubation using the anatomically existing route through the mouth is well suited for survival experiments. However, this procedure poses some challenges, including generally higher levels of the required experience and technical skill, more advanced equipment, and greater time effort with relevant intubation failure rates and complications such as tracheal perforation, temporary systemic hypooxygenation, and relevant aerial leakage. This manuscript, therefore, presents a detailed step-by-step protocol for endotracheal intubation through tracheotomy in non-survival rat models when guaranteed intubation success, constant oxygenation levels, high ventilation pressures, or open thoracotomy are required. The protocol emphasizes the importance of meticulous surgical technique to ensure consistent and reliable outcomes, especially for researchers who are inexperienced or lack routine in the technique of endoorotracheal intubation via direct laryngoscopy. This procedure is, therefore, expected to minimize animal suffering and unnecessary animal losses.


Thoracotomy , Tracheotomy , Animals , Rats , Intubation, Intratracheal/methods , Laryngoscopy/methods , Tracheostomy
19.
Medicina (Kaunas) ; 60(4)2024 Apr 10.
Article En | MEDLINE | ID: mdl-38674265

Background and Objectives: The ARNE score was developed for the prediction of a difficult airway for both general and ear, nose and throat (ENT) surgery with a universal cut-off value. We tested the accuracy of this score in the case of laryngeal surgery and provided an insight into its effects in combination with flexible laryngoscopy. Materials and Methods: This prospective pilot clinical study included 100 patients who were being scheduled for microscopic laryngeal surgery. We calculated the ARNE score for every patient, and flexible laryngoscopy was provided preoperative. Difficult intubation was assessed according to the intubation difficulty score (IDS). Results: A total of 33% patients had difficult intubation according to the IDS. The ARNE score showed limited accuracy for the prediction of difficult intubation in laryngology with p < 0.0001 and an AUC of 0.784. Flexible laryngoscopy also showed limitations when used as an independent parameter with p < 0.0001 and an AUC of 0.766. We defined a new cut-off value of 15.50 for laryngology, according to the AUC. After the patients were divided into two groups, according to the new cut-off value and provided cut-off value, the AUC improved to 0.707 from 0.619, respectively. Flexible laryngoscopy improved the prediction model of the ARNE score to an AUC of 0.882 and of the new cut-off value to an AUC of 0.833. Conclusions: It is recommended to use flexible laryngoscopy together with the ARNE score in difficult airway prediction in patients with laryngeal pathology. Also, the universally recommended cut-off value of 11 cannot be effectively used in laryngology, and a new cut-off value of 15.50 is recommended.


Intubation, Intratracheal , Laryngoscopy , Humans , Laryngoscopy/methods , Male , Prospective Studies , Female , Middle Aged , Aged , Intubation, Intratracheal/methods , Pilot Projects , Adult , Airway Management/methods , Airway Management/standards , Laryngeal Diseases/surgery , Laryngeal Diseases/physiopathology , Larynx/pathology
20.
Vet Anaesth Analg ; 51(3): 266-270, 2024.
Article En | MEDLINE | ID: mdl-38565449

OBJECTIVE: To develop and evaluate a low-cost three-dimensional (3D)-printed video laryngoscope (VLVET) for use with a commercial borescope. STUDY DESIGN: Instrument development and pilot study. ANIMALS: A total of six adult male Beagle dogs. METHODS: The VLVET consisted of a laryngoscope handle and a Miller-type blade, and a detachable camera holder that attached to various locations along the blade. The laryngoscope and camera holder were 3D-printed using black polylactic acid filament. Dogs were premedicated with intravenous (IV) medetomidine (15 µg kg-1) and anesthesia induced with IV alfaxalone (1.5 mg kg-1). The VLVET, combined with a borescope, was used for laryngeal visualization and intubation. Performance was evaluated by comparing direct and video-assisted views in sternal recumbency. The borescope camera was sequentially positioned at 2, 4, 6, 8 and 10 cm from the blade tip (distanceLARYNX-CAM), which was placed on the epiglottis during intubation or laryngoscopy. At the 10 cm distanceLARYNX-CAM, laryngeal visualization was sequentially scored at inter-incisor gaps of 10, 8, 6, 4 and 2 cm. Laryngeal visualization scores (0-3 range, with 0 = obstructed and 3 = unobstructed views) were statistically analyzed using the Friedman's test. RESULTS: Under direct visualization, the 2 cm distanceLARYNX-CAM had a significantly lower score compared with all other distanceLARYNX-CAM (all p = 0.014) because the view was obstructed by the camera holder and borescope camera. With both direct and camera-assisted views, visualization scores were higher at inter-incisor gaps ≥ 4 cm compared with 2 cm (all p < 0.05). CONCLUSIONS AND CLINICAL RELEVANCE: During laryngoscopy and intubation, the VLVET and borescope facilitated both direct and video laryngoscopy at distanceLARYNX-CAM in Beagle dogs when inter-incisor gaps were ≥ 4 cm.


Intubation, Intratracheal , Laryngoscopes , Printing, Three-Dimensional , Animals , Dogs , Laryngoscopes/veterinary , Male , Intubation, Intratracheal/veterinary , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods , Video Recording , Laryngoscopy/veterinary , Laryngoscopy/methods , Laryngoscopy/instrumentation , Pilot Projects , Equipment Design
...